桶蓋注塑成型工藝與模具設(shè)計(jì)
以上為資料預(yù)覽概圖,下載文件后為壓縮包資料文件。【清晰,無水印,可編輯】dwg后綴為cad圖,doc后綴為word格式,需要請(qǐng)自助下載即可,有疑問可以咨詢QQ 197216396 或 11970985
The technology of Microlens array injection moldingAbstract Injection molding could be used as a mass production technology for microlens arrays. It is of importance, and thus of our concern in the present study, to understand the injection molding processing condition effects on the replicability of microlens array profile. Extensive experiments were performed by varyingprocessing conditions such as flow rate, packing pressure and packing time for three different polymeric materials (PS, PMMA and PC). The nickel mold insert of microlens arrays was made by electroplating a microstructure master fabricated by a modified LIGA process. Effects of processing conditions on the replicability were investigated with the help of the surface profile measurements. Experimental results showed that a packing pressure and a flow rate significantly affects a final surface profile of the injection molded product. Atomic force microscope measurement indicated that the averaged surface roughness value of injection molded microlens arrays is smaller than that of mold insert and is comparable with that of fine optical components in practical use.1 Introduction Microoptical products such as microlenses or microlens arrays have been used widely in various fields of microoptics, optical data storages, bio-medical applications, display devices and so on. Microlenses and microlens arrays are essential elements not only for the practical applications but also for the fundamental studies in the microoptics. There have been several fabrication methods for microlenses or microlens arryas such as a modified LIGA process 1, photoresist reflow process 2, UV laser illumination 3, etc. And the replication techniques, such as injection molding, compression molding 4 and hot embossing 5, are getting more important for a mass production of microoptical products due to the cost-effectiveness. As long as the injection molding can replicate subtle microstructures well, it is surely the most cost-effective method in the mass production stage due to its excellent reproducibility and productivity. In this regard, it is of utmost importance to check the injection moldability and to determine the molding processing condition window for proper injection molding of microstructures. In this study, we investigated the effects of processing conditions on the replication of microlens arrays by the injection molding. The microlens arrays were fabricated by a modified LIGA process, which was previously reported in 6, 7. Injection molding experiments were performed with an electroplated nickel mold insert so as to investigate the effects of some processing conditions. The surface profiles of molded microlens arrays were measured, and were used to analyze effects of processing conditions. Finally, a surface roughness of microlens arrays was measured by an atomic force microscope (AFM).2 Mold insert fabricationMicrolens arrays having several different diameters were fabricated on a PMMA sheet by a modified LIGA process 6. This modified LIGA process is composed of an X-ray irradiation on the PMMA sheet and a subsequent thermal treatment. The X-ray irradiation causes the decrease of molecular weight of PMMA, which in turn decreases the glass transition temperature and consequently causes a net volume increase during the thermal cycle resulting in a swollen microlens 7. The shapes of microlenses fabricated by the modified LIGA process can be predicted by a method suggested in 7.The microlens arrays used in the experiments were composed of 500m -(a 2 2 array), 300m -(2 2) and 200m (5 5) diameter arrays, and their heights were 20.81, 17.21 and 8.06 m, respectively. Using the microlens arrays fabricated by the modified LIGA process as a master, a metallic mold insert was fabricated by a nickel electroplating for the injection molding. Typical materials used in a microfabrication process, such as silicon, photoresists or polymeric materials, cannot be directly used as the mold or the mold insert due to their weak strength or thermal properties. It is desirable to use metallic materials which have appropriate mechanical and thermal properties to endure both a high pressure and a large temperature variation during the replication process. Therefore, a metallic mold insert is being used rather than the PMMA master on silicon wafer for mass production with such replication techniques. Otherwise special techniques should be adopted as a replication method, e.g. a low pressure injection molding 8.The size of final electroplated mold insert was 30 30 3 mm. The electroplated nickel mold insert having microlens arrays is shown in Fig. 1.Fig.1.Moldinsert fabricated by a nickel electroplating (a) Real view of the mold insert (b) SEM image of 200 m diameter microlens array (c) SEM image of 300 mdiameter microlens array3 Injection molding experimentsA conventional injection molding machine (Allrounders 220 M, Arburg) was used in the experiments. A mold base for the injection molding was designed to fix the electroplated nickel mold insert firmly with the help of a frametype bolster plate (Fig. 2). Shape of aperture of the bolster plate (in this study, a rectangular one) defines the outer geometry of the molded part on which the profiles of microlens arrays are to be transcribed. The mold base itself has delivery systems such as sprue, runner and gate which lead the molten polymer to the cavity formed by the bolster plate, the mold insert and amoving mold surface. The mold base was designed such that mold insert replacement is simple and easy. Of course, one may introduce an appropriate bolster plate with a specific aperture shape. Fig. 2. Mold base and mold insert used in the injection molding experimentThe injection molding experiments were carried out with three general polymeric materials PS (615APR, Dow Chemical), PMMA (IF870, LG MMA) and PC (Lexan 141R, GE Plastics). These materials are quite commonly used for optical applications. They have different refractive indices (1.600, 1.490 and 1.586 for PS, PMMA and PC, respectively), giving rise to different optical properties in final products, e.g. different foci with the same geometry. The injectionmolding experiments were performed for seven processing conditions by changing flow rate, packing pressure and packing time for each polymeric material. Furthermore, same experiments were repeated three times for checking the reproducibility. It may be mentioned that the mold temperature effect was not considered in this study since the temperature effect is relatively less important for these microlens arrays due to their large radius of curvature than other microstructures of high aspect ratio. For high aspect ratio microstructures, we are currently investigating the temperature effect more closely and plan to report separately in the future. Therefore, flow rate, packing pressure and packing time were varied to investigate their effects more thoroughly with the mold temperature unchanged in this study. Table 1 shows the detailed processing conditions for three polymeric materials. Other processing conditions were kept unchanged during the experiment. The mold temperatures were set to 80, 70 and 60 _C for PC, PMMA and PS, respectively.It might be mentioned that we carried out the experiments without a vacuum condition in the mold cavity considering that the large radius of curvature of the microlens arrays in the present study will not entrap air in the microlens cavity during the filling stage.Table 1. Detailed processing conditions used in the injection molding experimentsCaseFlow rate (cc/sec)Packing time (sec)Packing pressure(MPa)112.05.010.0212.05.015.0312.05.020.0PS412.02.010.0512.010.010.0618.05.010.0724.05.010.0PMMA16.010.010.026.010.015.036.010.020.046.05.010.05676.09.012.015.010.010.010.010.010.0PC 16.05.05.026.05.010.0356.06.09.05.010.015.05.065.05.0712.05.05.04 Results and discussionBefore detailed discussion of the experimental results, it might be helpful to summarize why flow rate, packingpressure and packing time (which were chosen as processing conditions to be varied in this study) affect thereplication quality. As far as the flow rate is concerned, there may exist an optimal flow rate in the sense that too small flow rate makes too much cooling before a complete filling and thus possibly results in so-called short shot phenomena whereas too high flow rate increases pressure fields which is undesirable.The packing stage is generally required to compensate for the volume shrinkage of hot molten polymer whencooled down, so that enough material should flow into a mold cavity during this stage to control the dimensionalaccuracy. The higher the packing pressure, the longer the packing time, more material tends to flow in. However, too much packing pressure sometimes may cause uneven distribution of density, thereby resulting in poor opticalquality. And too long packing time does not help at all since gate will be frozen and prevent material from flowing into the cavity. In this regard, one needs to investigate the effects of packing pressure and packing time.4.1 Surface profilesFigure 3 shows typical scanning electron microscope (SEM) images of the injection molded microlens arrays for different diameters for PMMA (a) and different materials (b). Cross-sectional surface profiles of the mold insert and all the injection molded microlens arrays were measured by a 3D profile measuring system (NH-3N, Mitaka).(a)Injection molded microlensarrays (PMMA) (b) Injectionmolded microlenses of 300 mdiameter for different materialsFig. 3. SEM images of theinjection molded microlensarrays and microlensesAs a measure of replicability, we have defined a relative deviation of profile as the height difference between the molded one and the corresponding mold insert for each microlens divided by the mold insert one. The computed relative deviations for all the microlenses are listed in Table 2.Diameter( m)Relative deviation (%)1234567PS200300500-7.625.862.38-7.592.03-0.382.082.860.51-5.565.611.47-8.6660161.47-11.444.291.47-9.475.731.95PMMA2003005007.205.77-0.661.315.60-1.62-3.886.453.98-5.805.952.80-0.975.95-0.72-8.536.68-0.904.86-2.62-0.72PC20030050023.026.20-0.9316.054.965.0916.872.66-1.8619.664.531.8833.974.786.9618.671.792.43-2.944.15-1.55It may be mentioned that the moldability of polymeric materials affects the replicability. Therefore, the overall relative deviation differs for three polymeric materials used in this study. It may be noted that PC is the most difficult material for injection molding amongst the three polymers. The largest relative deviation can be found in PC for the smallest diameter case, as expected. In that specific case, the largest value is corresponding to the low flow rate and low packing pressure. Packing time in this case does not significantly affect the deviation. The relative deviation for PS and PMMA with the smallest diameter is far better than PC case.Table 2 indicates that the larger the diameter, the smaller the relative deviation. The larger diameter microlens is, of course, easier to be filled than smaller diameter during the filling stage and packing stage. Microlenses of larger diameters were generally replicated well regardless of processing conditions and regardless of materials. The best replicability is found for the case of PS with 500 m diameter. Generally, PS has a good moldability in comparison with PMMA and PC.It may be mentioned that some negative values of relative deviation were observed mostly in the smallest diameter case for PS and PMMA according to Table 2. In these cases, however, the absolute deviation is an order of 0.1 m in height, which is within the measurement error of the system. Therefore, the negative values could be ignored in interpreting the experimental data of replicability. Surface profiles of microlens of 300 m diameter are shown in Figs. 4 and 5 for PC and PMMA, respectively. As shown in Fig. 4, the higher packing pressure or the higher flow rate results in the better replication of microlens for the case of PC, as mentioned above. Packing time has little effect on the replication for these cases. For the case of PMMA, the packing pressure and packing time have insignificant effect as shown in Fig. 5; however, flow rate has the similar effect to PC. It might be reminded that packing time does not affect the replicability if a gate is frozen since frozen gate prevents material from flowinginto the cavity. Therefore, the effect of packing time disappears after a certain time depending on the processing conditions.Fig.4ac(leftside).Surfce profiles of microlens (PC with diameter (/) of 300 m). a effect of packing pressure, b effect of flow rate, c effectof packing timeFig.5ac.(rightside)Surface profiles of microlens (PMMA with diameter(/) of 300m). a effect of packing pressure, b effect of flow rate,c effect of packing time4.2 Surface roughnessAveraged surface roughness, Ra, values of 300 m diameter microlenses and the mold insert were measured by an atomic force microscope (Bioscope AFM, Digital Instruments). The measurements were performed around the top of each microlens and the measuring area was 5 m 5 m. Figure 6 shows AFM images and measured Ra values of microlenses. PMMA replicas of microlens have the lowest Ra value, 1.606 nm. It may be noted that AFM measurement indicated that Ra value of injection molded microlens arrays is smaller than the corresponding one of the mold insert. The reason for the improved surface roughness in the replicated microlens arrays is not clear at this moment, but might be attributed to the reflow caused by surface tension during a cooling process. It may be further noted that the Ra value of injection molded microlens arrays is comparable with that of fine optical components in practical use.a Nickel mold insert, b PS, c PMMA, d PCFig. 6. AFM images and averaged surface roughness, Ra, values of the mold insert and injection molded 300 m diameter microlenses.4.3 Focal lengthThe focal length of lenses can be calculated by a wellknown equation as follows:where f, nl, R1 and R2 are focal length, refractive index of lens material, two principal radii of curvature, respectively.For instance, focal lengths of the molded microlenses were approximately calculated as 1.065 mm (with R1 0.624 mm and R2 ¥) for 200 m diameter microlens, 1.130 mm (with R1= 0.662 mm and R2=) for 300 m microlens and 2.580 mm (with R1=1.512 mm and R2=) for 500 m microlens according to Eq. (1). These calculations were based on an assumption that microlenses are replicated with PC (nl= 1.586) and have the identical shape of the mold insert. It might be mentioned that the geometry of the molded microlens might be inversely deduced from an experimental measurement of the focal length.5 ConclusionThe replication of microlens arrays was carried out by the injection molding process with the nickel mold insert which was electroplated from the microlens arrays master fabricated via a modified LIGA process.The effects of processing conditions were investigated through extensive experiments conducted with various processing conditions. The results showed that the higher packing pressure or the higher flow rate is, the better replicability is achieved. In comparison, the packing time was found to have little effect on the replication of microlens arrays.The injection molded microlens arrays had a smaller averaged surface roughness values than the mold insert, which might be attributed to the reflow induced by surface tension during the cooling stage. And PMMA replicas of microlens arrays had the best surface quality (i.e. the lowest roughness value of Ra =1.606 nm). The surface roughness of injection molded microlens arrays is comparable with that of fine optical components in practical use. In this regard, injection molding might be a useful manufacturing tool for mass production of microlensarrays.Modern mold technologyIntroductionAlong with the global economy development, the new technological revolution made the new progress and the breakthrough unceasingly, the technical leap development already becomes the important attribute which the impetus world economics grew. The market economy unceasing development, urges the industry product more and more to the multi- varieties, high grade, the low cost direction to develop, in order to maintain and strengthens the product in market competitive power, product development cycle, production cycle more and more short, thereupon to makes each kind of product the essential craft equipment mold request to be more and more harsh. On the one hand the enterprise for the pursue scale benefit, causes the mold to turn towards high speed, is precise, the long life direction develops; On the other hand enterprise in order to satisfy the multi- varieties, the product renewal quickly, wins the market the need, requests the mold to turn towards the manufacture cycle to be short, the cost low fast economy direction develops. The computer, the laser, electronic, the new material, the new technical development, causes the fast economical pattern making technology even more powerful, the application scope expands unceasingly, the type increases unceasingly, the creation economic efficiency and the social efficiency are more and more remarkable. 1.Injection mold designThe injection molding application temperature dependence change material performance, through uses the mold to obtain the final shape separate part to complete or to complete the size close. In this kind of process of manufacture, the liquid material is compelled to fill, coagulates in the die space mold. first, must create a pattern mold to need a design model and carries the box. First, must create a pattern mold to need a design model and carries the box. The design model has represented the end product, but carries the box to represent the mold modules bulk volume. The injection mold design involves the mold structure and the function constituent widespread experience knowledge (heuristic knowledge). In the typical process molds the recent development to be possible to divide into four big stages: Product design, molds ability appraisal, part detailed design, insertion die space design and detailed mold design. in the initial stage, the product concept is in (usually is together a combination marketing and project) completes by several people. The initial stage main focal point is analyzes the market the opportunity and the adaptation strategy. In the first stage, the canonical correlation craft manufacture information is increased to the design, designs the geometry detail. The conceptual design use suitable manufacture information transforms as the goods which may make. In the second stage, the drawing of patterns direction and a minute hairs breadth buy for use examine molds ability. Otherwise, the components shape revises once more. In the third stage, the components geometry is uses for to establish the mold the core and the die space shape, the mold the core and the die space, will use for to form the components. Generally, the contraction and the expansion need to perform to consider, like this, in processes under the temperature, the formation will have the correct size and the shape. Th
收藏