歡迎來(lái)到裝配圖網(wǎng)! | 幫助中心 裝配圖網(wǎng)zhuangpeitu.com!
裝配圖網(wǎng)
ImageVerifierCode 換一換
首頁(yè) 裝配圖網(wǎng) > 資源分類(lèi) > DOC文檔下載  

機(jī)械專(zhuān)業(yè)外文翻譯(中英文翻譯)

  • 資源ID:7206000       資源大?。?span id="emws2ms" class="font-tahoma">104KB        全文頁(yè)數(shù):13頁(yè)
  • 資源格式: DOC        下載積分:10積分
快捷下載 游客一鍵下載
會(huì)員登錄下載
微信登錄下載
三方登錄下載: 微信開(kāi)放平臺(tái)登錄 支付寶登錄   QQ登錄   微博登錄  
二維碼
微信掃一掃登錄
下載資源需要10積分
郵箱/手機(jī):
溫馨提示:
用戶(hù)名和密碼都是您填寫(xiě)的郵箱或者手機(jī)號(hào),方便查詢(xún)和重復(fù)下載(系統(tǒng)自動(dòng)生成)
支付方式: 支付寶    微信支付   
驗(yàn)證碼:   換一換

 
賬號(hào):
密碼:
驗(yàn)證碼:   換一換
  忘記密碼?
    
友情提示
2、PDF文件下載后,可能會(huì)被瀏覽器默認(rèn)打開(kāi),此種情況可以點(diǎn)擊瀏覽器菜單,保存網(wǎng)頁(yè)到桌面,就可以正常下載了。
3、本站不支持迅雷下載,請(qǐng)使用電腦自帶的IE瀏覽器,或者360瀏覽器、谷歌瀏覽器下載即可。
4、本站資源下載后的文檔和圖紙-無(wú)水印,預(yù)覽文檔經(jīng)過(guò)壓縮,下載后原文更清晰。
5、試題試卷類(lèi)文檔,如果標(biāo)題沒(méi)有明確說(shuō)明有答案則都視為沒(méi)有答案,請(qǐng)知曉。

機(jī)械專(zhuān)業(yè)外文翻譯(中英文翻譯)

第13頁(yè) 外文翻譯英文原文Belt Conveying Systems Development of driving system Among the methods of material conveying employed,belt conveyors play a very important part in the reliable carrying of material over long distances at competitive costConveyor systems have become larger and more complex and drive systems have also been going through a process of evolution and will continue to do soNowadays,bigger belts require more power and have brought the need for larger individual drives as well as multiple drives such as 3 drives of 750 kW for one belt(this is the case for the conveyor drives in Chengzhuang Mine)The ability to control drive acceleration torque is critical to belt conveyors performanceAn efficient drive system should be able to provide smooth,soft starts while maintaining belt tensions within the specified safe limitsFor load sharing on multiple drivestorque and speed control are also important considerations in the drive systems design. Due to the advances in conveyor drive control technology,at present many more reliableCost-effective and performance-driven conveyor drive systems covering a wide range of power are available for customers choices1.1 Analysis on conveyor drive technologies11 Direct drivesFull-voltage startersWith a full-voltage starter design,the conveyor head shaft is direct-coupled to the motor through the gear driveDirect full-voltage starters are adequate for relatively low-power, simple-profile conveyorsWith direct fu11-voltage startersno control is provided for various conveyor loads anddepending on the ratio between fu11- and no-1oad power requirements,empty starting times can be three or four times faster than full loadThe maintenance-free starting system is simple,low-cost and very reliableHowever, they cannot control starting torque and maximum stall torque;thereforethey are limited to the low-power, simple-profile conveyor belt drivesReduced-voltage startersAs conveyor power requirements increase,controlling the applied motor torque during the acceleration period becomes increasingly importantBecause motor torque 1s a function of voltage,motor voltage must be controlledThis can be achieved through reduced-voltage starters by employing a silicon controlled rectifier(SCR)A common starting method with SCR reduced-voltage starters is to apply low voltage initially to take up conveyor belt slackand then to apply a timed linear ramp up to full voltage and belt speedHowever, this starting method will not produce constant conveyor belt accelerationWhen acceleration is completethe SCRs, which control the applied voltage to the electric motor are locked in full conduction, providing fu11-line voltage to the motorMotors with higher torque and pullup torque,can provide better starting torque when combined with the SCR starters, which are available in sizes up to 750 KWWound rotor induction motorsWound rotor induction motors are connected directly to the drive system reducer and are a modified configuration of a standard AC induction motorBy inserting resistance in series with the motors rotor windingsthe modified motor control system controls motor torqueFor conveyor starting,resistance is placed in series with the rotor for low initial torqueAs the conveyor accelerates,the resistance is reduced slowly to maintain a constant acceleration torqueOn multiple-drive systemsan external slip resistor may be left in series with the rotor windings to aid in load sharingThe motor systems have a relatively simple designHowever, the control systems for these can be highly complex,because they are based on computer control of the resistance switchingToday,the majority of control systems are custom designed to meet a conveyor systems particular specificationsWound rotor motors are appropriate for systems requiring more than 400 kW DC motorDC motorsavailable from a fraction of thousands of kW ,are designed to deliver constant torque below base speed and constant kW above base speed to the maximum allowable revolutions per minute(r/min)with the majority of conveyor drives, a DC shunt wound motor is usedWherein the motors rotating armature is connected externallyThe most common technology for controlling DC drives is a SCR device which allows for continual variable-speed operationThe DC drive system is mechanically simple, but can include complex custom-designed electronics to monitor and control the complete systemThis system option is expensive in comparison to other soft-start systemsbut it is a reliable, cost-effective drive in applications in which torque,1oad sharing and variable speed are primary considerationsDC motors generally are used with higher-power conveyors,including complex profile conveyors with multiple-drive systems,booster tripper systems needing belt tension control and conveyors requiring a wide variable-speed range12 Hydrokinetic couplingHydrokinetic couplings,commonly referred to as fluid couplingsare composed of three basic elements; the driven impeller, which acts as a centrifugal pump;the driving hydraulic turbine known as the runner and a casing that encloses the two power componentsHydraulic fluid is pumped from the driven impeller to the driving runner, producing torque at the driven shaftBecause circulating hydraulic fluid produces the torque and speed,no mechanical connection is required between the driving and driven shaftsThe power produced by this coupling is based on the circulated fluids amount and density and the torque in proportion to input speedBecause the pumping action within the fluid coupling depends on centrifugal forcesthe output speed is less than the input speedReferred to as slipthis normally is between l% and 3%Basic hydrokinetic couplings are available in configurations from fractional to several thousand kW Fixed-fill fluid couplingsFixed-fill fluid couplings are the most commonly used soft-start devices for conveyors with simpler belt profiles and limited convex/concave sectionsThey are relatively simple,1ow-cost,reliable,maintenance free devices that provide excellent soft starting results to the majority of belt conveyors in use todayVariable-fill drain couplingsDrainable-fluid couplings work on the same principle as fixed-fill couplingsThe couplings impellers are mounted on the AC motor and the runners on the driven reducer high-speed shaftHousing mounted to the drive base encloses the working circuitThe couplings rotating casing contains bleed-off orifices that continually allow fluid to exit the working circuit into a separate hydraulic reservoirOil from the reservoir is pumped through a heat exchanger to a solenoid-operated hydraulic valve that controls the filling of the fluid couplingTo control the starting torque of a single-drive conveyor system,the AC motor current must be monitored to provide feedback to the solenoid control valveVariable fill drain couplings are used in medium to high-kW conveyor systems and are available in sizes up to thousands of kW The drives can be mechanically complex and depending on the control parametersthe system can be electronically intricateThe drive system cost is medium to high, depending upon size specifiedHydrokinetic scoop control driveThe scoop control fluid coupling consists of the three standard fluid coupling components:a driven impeller, a driving runner and a casing that encloses the working circuitThe casing is fitted with fixed orifices that bleed a predetermined amount of fluid into a reservoirWhen the scoop tube is fully extended into the reservoir, the coupling is l00 percent filledThe scoop tube, extending outside the fluid coupling,is positioned using an electric actuator to engage the tube from the fully retracted to the fully engaged positionThis control provides reasonably smooth acceleration ratesto but the computer-based control system is very complexScoop control couplings are applied on conveyors requiring single or multiple drives from l50 kW to 750 kW.13 Variable-frequency control(VFC)Variable frequency control is also one of the direct drive methodsThe emphasizing discussion about it here is because that it has so unique characteristic and so good performance compared with other driving methods for belt conveyor VFC devices Provide variable frequency and voltage to the induction motor, resulting in an excellent starting torque and acceleration rate for belt conveyor drivesVFC drivesavailable from fractional to several thousand(kW ), are electronic controllers that rectify AC line power to DC and,through an inverter, convert DC back to AC with frequency and voltage contro1VFC drives adopt vector control or direct torque control(DTC)technology,and can adopt different operating speeds according to different loadsVFC drives can make starting or stalling according to any given S-curvesrealizing the automatic track for starting or stalling curvesVFC drives provide excellent speed and torque control for starting conveyor beltsand can also be designed to provide load sharing for multiple driveseasily VFC controllers are frequently installed on lower-powered conveyor drives,but when used at the range of medium-high voltage in the pastthe structure of VFC controllers becomes very complicated due to the limitation of voltage rating of power semiconductor devices,the combination of medium-high voltage drives and variable speed is often solved with low-voltage inverters using step-up transformer at the output,or with multiple low-voltage inverters connected in seriesThree-level voltage-fed PWM converter systems are recently showing increasing popularity for multi-megawatt industrial drive applications because of easy voltage sharing between the series devices and improved harmonic quality at the output compared to two-level converter systems With simple series connection of devicesThis kind of VFC system with three 750 kW /23kV inverters has been successfully installed in ChengZhuang Mine for one 27-km long belt conveyor driving system in following the principle of three-level inverter will be discussed in detail2 Neutral point clamped(NPC)three-level inverter using IGBTsThree-level voltage-fed inverters have recently become more and more popular for higher power drive applications because of their easy voltage sharing features1ower dv/dt per switching for each of the devices,and superior harmonic quality at the outputThe availability of HV-IGBTs has led to the design of a new range of medium-high voltage inverter using three-level NPC topologyThis kind of inverter can realize a whole range with a voltage rating from 23 kV to 41 6 kV Series connection of HV-IGBT modules is used in the 33 kV and 41 6 kV devicesThe 23 kV inverters need only one HV-IGBT per switch2,3.21 Power sectionTo meet the demands for medium voltage applicationsa three-level neutral point clamped inverter realizes the power sectionIn comparison to a two-level inverterthe NPC inverter offers the benefit that three voltage levels can be supplied to the output terminals,so for the same output current quality,only 1/4 of the switching frequency is necessaryMoreover the voltage ratings of the switches in NPC inverter topology will be reduced to 1/2and the additional transient voltage stress on the motor can also be reduced to 1/2 compared to that of a two-level inverter The switching states of a three-level inverter are summarized in Table 1UV and W denote each of the three phases respectively;P N and O are the dc bus pointsThe phase U,for example,is in state P(positive bus voltage)when the switches S1u and S2u are closed,whereas it is in state N (negative bus voltage) when the switches S3u and S4u are closedAt neutral point clamping,the phase is in O state when either S2u or S3u conducts depending on positive or negative phase current polarity,respectivelyFor neutral point voltage balancing,the average current injected at O should be zero22 Line side converterFor standard applicationsa l2-pulse diode rectifier feeds the divided DC-link capacitorThis topology introduces low harmonics on the line sideFor even higher requirements a 24-pulse diode rectifier can be used as an input converterFor more advanced applications where regeneration capability is necessary, an active frontend converter can replace the diode rectifier, using the same structure as the inverter23 Inverter controlMotor Contro1Motor control of induction machines is realized by using a rotor fluxoriented vector controllerFig2 shows the block diagram of indirect vector controlled drive that incorporates both constant torque and high speed field-weakening regions where the PW M modulator was usedIn this figure,the command flux is generated as function of speedThe feedback speed is added with the feed forward slip command signal . the resulting frequency signal is integrated and then the unit vector signals(cos and sin )are generatedThe vector rotator generates the voltage and angle commands for the PW M as shownPWM ModulatorThe demanded voltage vector is generated using an elaborate PWM modulatorThe modulator extends the concepts of space-vector modulation to the three-level inverterThe operation can be explained by starting from a regularly sampled sine-triangle comparison from two-level inverterInstead of using one set of reference waveforms and one triangle defining the switching frequency, the three-level modulator uses two sets of reference waveforms Ur1 and Ur2 and just one triangleThus, each switching transition is used in an optimal way so that several objectives are reached at the same time Very low harmonics are generatedThe switching frequency is low and thus switching losses are minimizedAs in a two-level inverter, a zero-sequence component can be added to each set of reference waveform s in order to maximize the fundamental voltage componentAs an additional degree of freedom,the position of the reference waveform s within the triangle can be changedThis can be used for current balance in the two halves of the DC-1ink3 Testing resultsAfter Successful installation of three 750 kW /23 kV three-level inverters for one 27 km long belt conveyor driving system in Chengzhuang MineThe performance of the whole VFC system was testedFig3 is taken from the test,which shows the excellent characteristic of the belt conveyor driving system with VFC controllerFig3 includes four curvesThe curve 1 shows the belt tensionFrom the curve it can be find that the fluctuation range of the belt tension is very smal1Curve 2 and curve 3 indicate current and torque separatelyCurve 4 shows the velocity of the controlled beltThe belt velocity have the“s”shape characteristicA1l the results of the test show a very satisfied characteristic for belt driving system4 ConclusionsAdvances in conveyor drive control technology in recent years have resulted in many more reliableCost-effective and performance-driven conveyor drive system choices for usersAmong these choices,the Variable frequency control (VFC) method shows promising use in the future for long distance belt conveyor drives due to its excellent performancesThe NPC three-level inverter using high voltage IGBTs make the Variable frequency control in medium voltage applications become much more simple because the inverter itself can provide the medium voltage needed at the motor terminals,thus eliminating the step-up transformer in most applications in the pastThe testing results taken from the VFC control system with NPC three1evel inverters used in a 27 km long belt conveyor drives in Chengzhuang Mine indicates that the performance of NPC three-level inverter using HV-IGBTs together with the control strategy of rotor field-oriented vector control for induction motor drive is excellent for belt conveyor driving system中文譯文:帶式輸送機(jī)及其牽引系統(tǒng) 在運(yùn)送大量的物料時(shí),帶式輸送機(jī)在長(zhǎng)距離的運(yùn)輸中起到了非常重要的競(jìng)爭(zhēng)作用。輸送系統(tǒng)將會(huì)變得更大、更復(fù)雜,而驅(qū)動(dòng)系統(tǒng)也已經(jīng)歷了一個(gè)演變過(guò)程,并將繼續(xù)這樣下去。如今,較大的輸送帶和多驅(qū)動(dòng)系統(tǒng)需要更大的功率,比如3驅(qū)動(dòng)系統(tǒng)需要給輸送帶750KW (成莊煤礦輸送機(jī)驅(qū)動(dòng)系統(tǒng)的要求)。控制驅(qū)動(dòng)力和加速度扭矩是輸送機(jī)的關(guān)鍵。一個(gè)高效的驅(qū)動(dòng)系統(tǒng)應(yīng)該能順利的運(yùn)行,同時(shí)保持輸送帶張緊力在指定的安全極限負(fù)荷內(nèi)。為了負(fù)載分配在多個(gè)驅(qū)動(dòng)上,扭矩和速度控制在驅(qū)動(dòng)系統(tǒng)的設(shè)計(jì)中也是很重要的因素。由于輸送機(jī)驅(qū)動(dòng)系統(tǒng)控制技術(shù)的進(jìn)步,目前更多可靠的低成本和高效驅(qū)動(dòng)的驅(qū)動(dòng)系統(tǒng)可供顧客選擇1。1 帶式輸送機(jī)驅(qū)動(dòng)1.1 帶式輸送機(jī)驅(qū)動(dòng)方式全電壓?jiǎn)?dòng) 在全電壓?jiǎn)?dòng)設(shè)計(jì)中,帶式輸送機(jī)驅(qū)動(dòng)軸通過(guò)齒輪傳動(dòng)直接連接到電機(jī)。直接全壓驅(qū)動(dòng)沒(méi)有為變化的傳送負(fù)載提供任何控制,根據(jù)滿(mǎn)載和空載功率需求的比率,空載啟動(dòng)時(shí)比滿(mǎn)載可能快34倍。此種方式的優(yōu)點(diǎn)是:免維護(hù),啟動(dòng)系統(tǒng)簡(jiǎn)單,低成本,可靠性高。但是,不能控制啟動(dòng)扭矩和最大停止扭矩。因此,這種方式只用于低功率,結(jié)構(gòu)簡(jiǎn)單的傳送驅(qū)動(dòng)中。降壓?jiǎn)?dòng) 隨著傳送驅(qū)動(dòng)功率的增加,在加速期間控制使用的電機(jī)扭矩變得越來(lái)越重要。由于電機(jī)扭矩是電壓的函數(shù),電機(jī)電壓必須得到控制,一般用可控硅整流器(SCR) 構(gòu)成的降壓?jiǎn)?dòng)裝置,先施加低電壓拉緊輸送帶,然后線(xiàn)性的增加供電電壓直到全電壓和最大帶速。但是,這種啟動(dòng)方式不會(huì)產(chǎn)生穩(wěn)定的加速度,當(dāng)加速完成時(shí),控制電機(jī)電壓的SCR 鎖定在全導(dǎo)通,為電機(jī)提供全壓。此種控制方式功率可達(dá)到750kW。繞線(xiàn)轉(zhuǎn)子感應(yīng)電機(jī) 繞線(xiàn)轉(zhuǎn)子感應(yīng)電機(jī)直接連接到驅(qū)動(dòng)系統(tǒng)減速機(jī)上,通過(guò)在電機(jī)轉(zhuǎn)子繞組中串聯(lián)電阻控制電機(jī)轉(zhuǎn)矩。在傳送裝置啟動(dòng)時(shí),把電阻串聯(lián)進(jìn)轉(zhuǎn)子產(chǎn)生較低的轉(zhuǎn)矩,當(dāng)傳送帶加速時(shí),電阻逐漸減少保持穩(wěn)定增加轉(zhuǎn)矩。在多驅(qū)動(dòng)系統(tǒng)中,一個(gè)外加的滑差電阻可能將總是串聯(lián)在轉(zhuǎn)子繞組回路中以幫助均分負(fù)載。該方式的電機(jī)系統(tǒng)設(shè)計(jì)相對(duì)簡(jiǎn)單,但控制系統(tǒng)可能很復(fù)雜,因?yàn)樗鼈兪腔谟?jì)算機(jī)控制的電阻切換。當(dāng)今,控制系統(tǒng)的大多數(shù)是定制設(shè)計(jì)來(lái)滿(mǎn)足傳送系統(tǒng)的特殊規(guī)格。繞線(xiàn)轉(zhuǎn)子電機(jī)適合于需要400kW以上的系統(tǒng)。直流(DC)電機(jī) 大多數(shù)傳送驅(qū)動(dòng)使用DC 并勵(lì)電機(jī),電機(jī)的電樞在外部連接??刂艱C 驅(qū)動(dòng)技術(shù)一般應(yīng)用SCR裝置,它允許連續(xù)的變速操作。DC 驅(qū)動(dòng)系統(tǒng)在機(jī)械上是簡(jiǎn)單的,但設(shè)計(jì)的電子電路,監(jiān)測(cè)和控制整個(gè)系統(tǒng),相比于其他軟啟動(dòng)系統(tǒng)的選擇是昂貴的,但在轉(zhuǎn)矩、負(fù)載均分和變速為主要考慮的場(chǎng)合,它又是一個(gè)可靠的,節(jié)約成本的方式。DC 電機(jī)一般使用在功率較大的輸送裝置上,包括需要輸送帶張力控制的多驅(qū)動(dòng)系統(tǒng)和需要寬變速范圍的輸送裝置上。1.2 液力偶合器流體動(dòng)力偶合器通常被稱(chēng)為液力偶合器,由三個(gè)基本單元組成:充當(dāng)離心泵的葉輪,推進(jìn)水壓的渦輪和裝進(jìn)兩個(gè)動(dòng)力部件的外殼。流體從葉輪到渦輪,在從動(dòng)軸產(chǎn)生扭矩。由于循環(huán)流體產(chǎn)生扭矩和速度,在驅(qū)動(dòng)軸和從動(dòng)軸之間不需要任何機(jī)械連接。這種連接產(chǎn)生的動(dòng)力決定于液力偶合器的充液量,扭矩正比于輸入速度。因在流體偶合中輸出速度小于輸入速度,其間的差值稱(chēng)為滑差,一般為1 %3 %。傳遞功率可達(dá)幾千千瓦。固定充液液力偶合器 固定充液液力偶合器是在結(jié)構(gòu)較簡(jiǎn)單和僅具有有限的彎曲部分的輸送裝置中最常用的軟啟動(dòng)裝置,其結(jié)構(gòu)相對(duì)比較簡(jiǎn)單,成本又低,對(duì)現(xiàn)在使用的大多數(shù)輸送機(jī)能提供優(yōu)良的軟啟動(dòng)效果??勺兂湟阂毫ε己掀?也稱(chēng)為限矩型液力偶合器。偶合器的葉輪裝在AC 電機(jī)上,渦輪裝在從動(dòng)減速器高速軸上,包含操作部件的軸箱安裝在驅(qū)動(dòng)基座。偶合器的旋轉(zhuǎn)外殼有溢出口,允許液體不斷地從工作腔中流出進(jìn)入一個(gè)分離的輔助腔,油從輔助腔通過(guò)一個(gè)熱交換器泵到控制偶合器充液量的電磁閥。為了控制單機(jī)傳動(dòng)系統(tǒng)的啟動(dòng)轉(zhuǎn)矩,必須監(jiān)測(cè)AC 電機(jī)電流,給電磁閥的控制提供反饋??勺兂湟阂毫ε己掀骺墒褂迷谥写蠊β瘦斔拖到y(tǒng)中,功率可達(dá)到數(shù)千千瓦。這種驅(qū)動(dòng)無(wú)論在機(jī)械,或在電氣上都是很復(fù)雜的,其驅(qū)動(dòng)系統(tǒng)成本中等。勺管控制液力偶合器 也稱(chēng)為調(diào)速型液力偶合器。此種液力偶合器同樣由三個(gè)標(biāo)準(zhǔn)的液力偶合單元構(gòu)成,即葉輪、渦輪和一個(gè)包含工作環(huán)路的外殼。此種液力偶合器需要在工作腔以外設(shè)置導(dǎo)管(也稱(chēng)勺管) 和導(dǎo)管腔,依靠調(diào)節(jié)裝置改變勺管開(kāi)度(勺管頂端與旋轉(zhuǎn)外殼間距) 人為的改變工作腔的充液量,從而實(shí)現(xiàn)對(duì)輸出轉(zhuǎn)速的調(diào)節(jié)。這種控制提供了合理的平滑加速度,但其計(jì)算機(jī)控制系統(tǒng)很復(fù)雜。勺管控制液力偶合器可以應(yīng)用在單機(jī)或多機(jī)驅(qū)動(dòng)系統(tǒng), 功率范圍為150kW750kW。13 變頻控制(VFC)變頻控制也是一種直接驅(qū)動(dòng)方式,它具有非常獨(dú)特的高性能。VFC 裝置為感應(yīng)電機(jī)提供變化的頻率和電壓,產(chǎn)生優(yōu)良的啟動(dòng)轉(zhuǎn)矩和加速度。VFC設(shè)備是一個(gè)電力電子控制器,首先把AC 整流成DC ,然后利用逆變器,再將DC 轉(zhuǎn)換成頻率、電壓可控的AC。VFC 驅(qū)動(dòng)采用矢量控制或直接轉(zhuǎn)矩控制(DTC) 技術(shù),能根據(jù)不同的負(fù)載采用不同的運(yùn)行速度。VFC 驅(qū)動(dòng)能根據(jù)給定的S 曲線(xiàn)啟動(dòng)或停車(chē),實(shí)現(xiàn)自動(dòng)跟蹤啟動(dòng)或停車(chē)曲線(xiàn)。VFC 驅(qū)動(dòng)為傳送帶啟動(dòng)提供了優(yōu)良的速度和轉(zhuǎn)矩控制,也能為多機(jī)驅(qū)動(dòng)系統(tǒng)提供負(fù)載均分。VFC 控制器可以容易地裝在小功率輸送機(jī)驅(qū)動(dòng)上。過(guò)去在中高電壓使用時(shí),VFC 設(shè)備的結(jié)構(gòu)由于受電力半導(dǎo)體器件的電壓額定值限制而變得很復(fù)雜,中高電壓的變速傳動(dòng)常常使用低壓逆變器,然后在輸出端使用升壓變壓器,或使用多個(gè)低壓逆變器串聯(lián)來(lái)解決。與簡(jiǎn)單的器件串聯(lián)連接的兩電平逆變器系統(tǒng)比較,由于串聯(lián)器件之間容易均壓以及輸出端可以有更好的諧波特性,三電平電壓型PWM 逆變器系統(tǒng)在數(shù)兆瓦工業(yè)傳動(dòng)中近年來(lái)獲得了越來(lái)越多的應(yīng)用。由三臺(tái)750kW/ 2. 3kV 的這種逆變器構(gòu)成的VFC 系統(tǒng)已經(jīng)成功安裝在成莊煤礦長(zhǎng)2. 7km的帶式輸送機(jī)驅(qū)動(dòng)系統(tǒng)中。2 使用IGBT的中性點(diǎn)箝位三電平逆變器由于串聯(lián)器件電壓均分容易,器件每次開(kāi)關(guān)的d v/ d t 低以及輸出端出色的諧波品質(zhì),三電平電壓型逆變器在大功率傳動(dòng)應(yīng)用中變得越來(lái)越流行。高壓IGBT(HV-IGBT) 的出現(xiàn)使得應(yīng)用三電平中性點(diǎn)箝位原理的中高壓逆變器設(shè)計(jì)有了更大的應(yīng)用范圍。這種逆變器目前可以實(shí)現(xiàn)從2. 3kV到4. 16kV全范圍的應(yīng)用。HV-IGBT 模塊串聯(lián)可使用在3. 3kV和4. 16kV的設(shè)備。2. 3kV逆變器每個(gè)開(kāi)關(guān)只需要一個(gè)HV-IGBT2,3。21 主功率逆變電路主功率逆變電路用三電平中點(diǎn)箝位電壓型逆變器實(shí)現(xiàn),可以滿(mǎn)足中高壓交流傳動(dòng)應(yīng)用的需要。與兩電平電壓型逆變器相比,三電平中點(diǎn)箝位電壓型逆變器提供三個(gè)電壓級(jí)別給輸出端,對(duì)于同樣的輸出電流品質(zhì),開(kāi)關(guān)頻率可降低到原來(lái)的1/ 4,開(kāi)關(guān)器件的電壓額定值可減小到原來(lái)的1/ 2 ,附加到電機(jī)上的額外的瞬態(tài)電壓應(yīng)力也可能減少到原來(lái)的1/ 2 。三電平中點(diǎn)箝位電壓型逆變器的開(kāi)關(guān)狀態(tài)可歸納于表1 ,U ,V 和W 分別表示三相, P,N 和O 是直流母線(xiàn)上的三個(gè)點(diǎn)。例如,當(dāng)開(kāi)關(guān)S1U和S2U閉合時(shí),U 相處于狀態(tài)P(正母線(xiàn)電壓) ,反之,當(dāng)開(kāi)關(guān)S3U和S4U閉合時(shí),U 相處于狀態(tài)N (負(fù)母線(xiàn)電壓) 。在中性點(diǎn)箝位時(shí),該相在O 狀態(tài),這時(shí)根據(jù)相電流極性的正負(fù),或者是S2U導(dǎo)通或者是S3U導(dǎo)通。為了保證中性點(diǎn)電壓平衡,在O 點(diǎn)被注入的平均電流應(yīng)該是零。2.2 輸入端變流器為通常使用12 脈沖二極管整流器給直流環(huán)節(jié)電容器充電,在輸入端引入的諧波是很小的。若對(duì)輸入諧波有更高的要求,可以使用24 脈沖二極管整流器作為輸入變流器。對(duì)于需要有再生能力的更高級(jí)應(yīng)用,可以用一個(gè)有源輸入變流器取代二極管整流器,這時(shí)輸入整流器與輸出逆變器為同一結(jié)構(gòu)。2.3 逆變器控制電機(jī)控制 感應(yīng)電機(jī)的控制可以使用轉(zhuǎn)子磁場(chǎng)定向矢量控制器實(shí)現(xiàn),通過(guò)使用PWM 調(diào)制器完成了恒轉(zhuǎn)矩區(qū)和高速弱磁區(qū)的控制。圖2 為間接矢量控制框圖。圖中指令磁通r 是速度的函數(shù),反饋速度和前饋滑差控制信號(hào)sl相加。對(duì)相加結(jié)果的頻率信號(hào)積分,然后產(chǎn)生單位矢量(cose 和sine ) ,最后通過(guò)矢量旋轉(zhuǎn)器產(chǎn)生電壓角控制PWM 調(diào)制器。PWM調(diào)制器 該調(diào)制器實(shí)際上是把空間矢量調(diào)制概念擴(kuò)展到三電平逆變器。其基本原理是三電平PWM 調(diào)制器使用兩個(gè)參考波Ur1 和Ur2,但只使用一個(gè)三角波。它以一種優(yōu)化方式確定每一次開(kāi)關(guān)時(shí)刻。產(chǎn)生的諧波盡可能的小,使用盡可能低的開(kāi)關(guān)頻率以最小化開(kāi)關(guān)損耗;可將零序成分加到每一個(gè)參考波里以便最大化基波電壓。作為一個(gè)附加的自由度,參考波與三角波的相對(duì)位置可改變,這可以用于直流環(huán)節(jié)中點(diǎn)的電流平衡。3 測(cè)試結(jié)果三個(gè)750kW/ 2. 3kV 三電平逆變器在成莊煤礦2. 7km 長(zhǎng)帶式輸送機(jī)驅(qū)動(dòng)系統(tǒng)成功安裝之后,對(duì)整個(gè)變頻傳動(dòng)系統(tǒng)(VFC) 的性能進(jìn)行了測(cè)試,測(cè)試結(jié)果顯示出使用VFC 控制系統(tǒng)的帶式輸送機(jī)的優(yōu)良特性。圖3為測(cè)試結(jié)果波形。由圖看出,曲線(xiàn)1 顯示受控帶速,帶速呈S 形曲線(xiàn)形狀,曲線(xiàn)2 、3 分別表示電流和扭矩,曲線(xiàn)4 顯示帶張力。從圖中可以發(fā)現(xiàn),帶張力的波動(dòng)范圍很小,所有檢測(cè)結(jié)果顯示出帶式輸送機(jī)驅(qū)動(dòng)系統(tǒng)令人滿(mǎn)意的特性。4 結(jié)論近年來(lái)輸送機(jī)驅(qū)動(dòng)控制技術(shù)的進(jìn)步已更為可靠,符合低成本效益和高效驅(qū)動(dòng)的驅(qū)動(dòng)系統(tǒng)為用戶(hù)提供了選擇。在這些選擇中,可變頻率控制(VFC)的方法顯現(xiàn)出在將來(lái)長(zhǎng)距離輸送中帶式輸送機(jī)扮演了重要的角色。使用高壓IGBT 的中點(diǎn)嵌位三電平逆變器本身可以提供電機(jī)終端所需的供電中高壓,使變頻控制的應(yīng)用更為簡(jiǎn)單。通過(guò)成

注意事項(xiàng)

本文(機(jī)械專(zhuān)業(yè)外文翻譯(中英文翻譯))為本站會(huì)員(QQ-1****6396)主動(dòng)上傳,裝配圖網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶(hù)上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)上載內(nèi)容本身不做任何修改或編輯。 若此文所含內(nèi)容侵犯了您的版權(quán)或隱私,請(qǐng)立即通知裝配圖網(wǎng)(點(diǎn)擊聯(lián)系客服),我們立即給予刪除!

溫馨提示:如果因?yàn)榫W(wǎng)速或其他原因下載失敗請(qǐng)重新下載,重復(fù)下載不扣分。




關(guān)于我們 - 網(wǎng)站聲明 - 網(wǎng)站地圖 - 資源地圖 - 友情鏈接 - 網(wǎng)站客服 - 聯(lián)系我們

copyright@ 2023-2025  zhuangpeitu.com 裝配圖網(wǎng)版權(quán)所有   聯(lián)系電話(huà):18123376007

備案號(hào):ICP2024067431號(hào)-1 川公網(wǎng)安備51140202000466號(hào)


本站為文檔C2C交易模式,即用戶(hù)上傳的文檔直接被用戶(hù)下載,本站只是中間服務(wù)平臺(tái),本站所有文檔下載所得的收益歸上傳人(含作者)所有。裝配圖網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶(hù)上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)上載內(nèi)容本身不做任何修改或編輯。若文檔所含內(nèi)容侵犯了您的版權(quán)或隱私,請(qǐng)立即通知裝配圖網(wǎng),我們立即給予刪除!